Assessment of Carbon/Salt/Adhesive Electrodes for Surface Electromyography Measurements

May 24, 2016

Hugo Posada-Quintero, Ryan Rood, Ken Burnham, John Pennace, Ki Chon

Assessment of Carbon/Salt/Adhesive Electrodes for Surface Electromyography Measurements

This work presents the evaluation of novel electrodes for surface electromyography (sEMG) measurements. The electrodes are based on a mixture of carbon powder, quaternary salt and viscoelastic polymeric adhesive (carbon/salt/adhesive or simply CSA), which when combined, provide the unique advantages of having longer (theoretically infinite) shelf life and potentially lower cost than Ag/AgCl hydrogel electrodes, consistent with FLEXcon’s Patent #8,673,184. Twenty subjects were recruited to collect simultaneous recordings of sEMG signals using Ag/AgCl and CSA electrodes, side-by-side on triceps brachii, tibial anterior muscles, biceps brachii and quadriceps femoris. Although CSA sEMG electrodes showed higher electrode-skin contact impedance for the frequency range of 4 Hz to 2 kHz, no significant differences were found in the signals’ amplitude between the two electrodes either during relaxation or contraction stages. Furthermore, correlations of the computed linear envelopes (>0.91), RMS value envelopes (>0.91) and power spectral densities (>0.95) of the signals were found to be high between the two media. Detected on- and off-times of contraction were also highly correlated (>0.9) and interchangeable (on-time: bias = -0.02, variance = 0.11; off-time: bias = -0.04, variance = 0.23) between the two media. However, CSA sEMG electrodes exhibited a significantly better response to noise (38.3 ± 10.6 dB vs. 32.7 ± 15.6 dB) and motion artifacts (24.1 ± 12.1 dB vs. 16.6 ± 8.52 dB), and a significantly lower spectral deformation (1.32 ± 0.2 vs. 1.46 ± 0.4). Ag/AgCl electrodes showed a significantly more peaked and sensitive response to EMG amplitude (67.9 ± 13.9 dB vs. 65.4 ± 14.6). Given no significant differences in many of the measures described above and the fact that CSA electrodes have an infinite shelf-life, are potentially lower cost, and are more resistant to motion artifacts, the new electrodes provide an attractive alternative to Ag/AgCl electrodes for sEMG measurements.

READ FULL ARTICLE ON IEEE XPLORE

Login

New Here? Sign Up

Looking for increased exposure in the field of biomedical engineering? EMBS offers journals, conferences and a community for biomedical engineers. Membership includes PULSE Magazine.

Join EMBS